The previous design did not actually break from the wait loop when the
AP changed back to 40 MHz channel and as such, ended up waiting the full
30 second time. Furthermore, the five second delay time for returning
back to 40 MHz was not sufficiently long to test behavior correctly
since the STA did not have any chances of returning the next coex report
before the AP had returned to 40 MHz. Increase the AP wait time to 15
seconds so that the once per 10 seconds OBSS scan from the STA gets in
before changing back to 40 MHz channel (after the 40 MHz intolerant AP
gets disabled).
Signed-off-by: Jouni Malinen <j@w1.fi>
Use a single iteration through the module dictionary rather than
iterating over the keys and separately fetching values to get the
function.
Signed-off-by: Jouni Malinen <j@w1.fi>
There is no need to wait for one extra second to chown log files when
running as root which is always the case in VM execution.
Signed-off-by: Jouni Malinen <j@w1.fi>
These test cases had a long 120 seconds wait for the GO Negotiation
initiator to time out. This can be done using two devices in parallel to
save two minutes from total test execution time.
Signed-off-by: Jouni Malinen <j@w1.fi>
This function did not seem to do anything else apart from making it less
obvious that hwsim_utils.test_connectivity() is called.
Signed-off-by: Jouni Malinen <j@w1.fi>
Wait one second between each kvm start to avoid hitting large number of
processes trying to start in parallel. This allows the VMs to be started
more efficiently for parallel-vm.py runs with large number of VMs.
Signed-off-by: Jouni Malinen <j@w1.fi>
It was possible for the hidden SSID entry to leak into following test
cases and result in failures, e.g., in this sequence:
scan_hidden
scan_reqs_with_non_scan_radio_work
radius_auth_unreachable
wep_open_auth
BSS <BSSID> picked incorrect BSS entry within wpa_supplicant due to the
old zero-length SSID showing up from the earlier hidden SSID case.
Signed-off-by: Jouni Malinen <j@w1.fi>
Move test cases with long duration to the beginning as an optimization
to avoid last part of the test execution running a long duration test
case on a single VM while all other VMs have already completed their
work.
Signed-off-by: Jouni Malinen <j@w1.fi>
Now there is only one set of commands to maintain. The separate reports
for individual components have not been of much use in the past, so they
are dropped for now.
Signed-off-by: Jouni Malinen <j@w1.fi>
There is no need to wait for the timeout if the ROAM command itself
failed. This could happen if an earlier test case had left hidden SSIDs
in the cfg80211 BSS table.
Signed-off-by: Jouni Malinen <j@w1.fi>
Leaving hidden SSIDs in the cfg80211 BSS table can result in errors in
the following test cases, so use special care to clear all BSS entries
at the end of the wext_hidden test case.
Signed-off-by: Jouni Malinen <j@w1.fi>
This allows code coverage report to be generated must faster with the
help of parallel VMs executing test cases.
Signed-off-by: Jouni Malinen <j@w1.fi>
This verifies that offchannel TX (PD in this specific case) does not
stop ongoing long P2P_LISTEN operation.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
There were couple of typos in the IP addresses and there was no coverage
for the normal unicast ARP response from the bridge (since non-wireless
device does not get proxied by the AP). In addition, it is better to
change the IP address used here to be unique to make the sniffer logs
easier to interpret.
Signed-off-by: Jouni Malinen <j@w1.fi>
This adds transmission of number of NS/NA frames to test ProxyARP
behavior. The actual validation of the AP behavior is still manual,
i.e., a separate inspectation of the capture files is needed.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This may be needed in some corner cases where broadcast frames with two
associated stations are received by both devices.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
The final invitation case in this test was verified incorrectly. The GO
was already operatign in that case, so there was not supposed to be a
new P2P-GROUP-STARTED message from GO. That happened to be show up in
the pending event messages from the last instance, but that was just by
accident and any additional dump_monitor() operation added here would
cause this test to fail. Fix this by handling the final invitation
separately and verifying that only the client side indicates
P2P-GROUP-STARTED.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
It is possible for WpaSupplicant instance to be used without the global
control socket, so allow dump_monitor() to handle this case cleanly.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>