This was found through a mac80211 bug which didn't correctly accept a
center segment 0 value of zero, so the test will fail until the mac80211
bug is fixed.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This allows a critical error to be noticed more quickly and reported
more clearly in the test log.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
Some kernel debugging options (especially
CONFIG_DEBUG_KOBJECT_RELEASE=y) can add significant blocking time to
interface removal with NL80211_CMD_DEL_INTERFACE and
SIOCGIFBR(BRCTL_DEL_BRIDGE) block for 1-8 seconds. This could result in
the VLAN test cases failing due to a wpaspy timeout on the REMOVE
command even though the issue was only in the kernel debugging code
making the operations significantly slower. Work around this by using a
longer timeout for that control interface command to allow this type of
debug kernel to be used.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
If trace-cmd command does not exist, run-tests.py could end up hanging
in a loop waiting for input. Fix this simply by checking whether the
trace-cmd command can be executed sucessfully and exiting the script if
not.
Signed-off-by: Eduardo Abinader <eduardo.abinader@openbossa.org>
Both the output file path and the current working directory included the
log directory and this failed if log directory was not absolute (e.g.,
when using the default logs/current in the case a VM is not used).
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
The return value was lost and GCMP, CCMP-256, and GCMP-256 test cases
were reporting PASS instead of SKIP.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
Verify that session information is stored from Access-Accept and sent to
the station at the requested timeout. Verify that station processes this
notification.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This verifies that hostapd can add extra RADIUS attributes using
radius_auth_req_attr and radius_acct_req_attr.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
Fix updating of the current symbolic link when LOGDIR is already set.
The current symbolic link was only set, if LOGDIR has not been
previously defined. If the user had chosen to cancel the running test
iteration and run it again by running start.sh again, the current
symbolic link was not updated.
Signed-off-by: Eduardo Abinader <eduardo.abinader@openbossa.org>
This commit includes number of test frames for attribute parsing.
Invitation Request and Provision Discovery processing is also covered.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is the older design that some drivers may still use if they do not
support offloaded offchannel TX operations.
Signed-off-by: Jouni Malinen <j@w1.fi>
A bit different code path is used to match the first three different
locations of roaming consortium OI within Beacon frame.
Signed-off-by: Jouni Malinen <j@w1.fi>
Wait a bit between WPS_CONFIG command and the first scan. This can avoid
an extra five second wait due to having to scan again if the initial
scan operations happens to be quick enough to happen before the AP has
updated its configuration.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This verifies that 'INTERWORKING_SELECT auto' is able to pick the
correct network based on priority configuration when connected to a
lower priority network.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
test_ap_hs20_multi_cred_sp_prio verifies that two credentials
provisioned by a single SP are selected properly based on sp_priority
when a single BSS matches both credentials.
test_ap_hs20_multi_cred_sp_prio2 does the same when there a separate BSS
for each credential.
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
This verifies that 'INTERWORKING_SELECT auto' is able to roam to a
higher priority network when executed while connected to a lower
priority network.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add a new option to set the use_chanctx flag when creating a radio.
While at it, refactor the arguments parsing code to use argparse.
Signed-hostap: Luciano Coelho <luciano.coelho@intel.com>
This seems to be needed in some cases to avoid issues in test cases that
assume there are no other ERs running.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This makes the script check the environment for the current python
interpreter in use instead of assuming that the python executable points
to a python 2 interpreter.
Signed-off-by: Roger Zanoni <roger.zanoni@openbossa.org>
Only run-tests.py is actually executed, so there is no need to specify
the interpreter in all the helper files and test script files.
Signed-off-by: Jouni Malinen <j@w1.fi>
CONFIG_MODULE_TESTS=y build option can now be used to build in module
tests into hostapd and wpa_supplicant binaries. These test cases will be
used to get better testing coverage for various details that are
difficult to test otherwise through the control interface control. A
single control interface command is used to executed these tests within
the hwsim test framework. This commit adds just the new mechanism, but no
module tests are yet integrated into this mechanism.
Signed-off-by: Jouni Malinen <j@w1.fi>
Verify cases both with multiple peers (one of which not advertising any
services) and with multiple SD queries.
Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>