In addition, update the generation script to allow convenient update of
the server and user certificates without having to generate new keys.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The wlan.mesh.config doesn't have to be the last element of beacon. Things
like VHT or HE oper/cap are usually follow the mesh configuration element.
The workaround must first get the position of a correct reference value in
wlan.mesh.config (ps_protocol) and then calculate the correct
wlan.mesh.config.cap offset based on that.
Reported-by: Johannes Berg <johannes@sipsolutions.net>
Fixes: 2cbaf0de22 ("tests: Work around tshark bug in wpas_mesh_max_peering")
Signed-off-by: Sven Eckelmann <sven@narfation.org>
It was clearly too easy to get unexpected behavior by accidentially
passing in a string instead of a list of strings to these functions, so
enforce the correct type to notice such issues automatically.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
wait_event() expects a list of events instead of a single event name.
The previous implementation of wait_sta() did not really wait for
AP-STA-CONNECT; instead, it returned the next event from hostapd
regardless of what that event was.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The AP side may not have had enough time to configure the new TK into
the driver if the connectivity test is started immediately after the
station side event.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
When going through 4-way handshake, the station side reports
CTRL-EVENT-CONNECTED after having sent out EAPOL-Key msg 4/4. The AP
side reports AP-STA-CONNECT after having completed processing of this
frame. Especially when using UML with time travel, it is possible for
the connectivity test to be started before the AP side has configured
the pairwise TK if the test is triggered based on CTRL-EVENT-CONNECTED
instead of AP-STA-CONNECT.
Add explicit wait for AP-STA-CONNECT in some of these cases to reduce
likelihood of reporting failures for test cases that are actually
behaving as expected. This shows up with "dev1->dev2 unicast data
delivery failed" in the test log.
Do the same before requesting reauthentication from the station side
since that has a similar issue with the EAPOL-Start frame getting
encrypted before the AP is ready for it.
Signed-off-by: Jouni Malinen <j@w1.fi>
This helps in avoiding issues with another test case trying to bind to
the same UDP port and failing due to the previous use by pyrad still
being open. This showed up with failures in radius_ipv6 when it followed
a test case like eap_proto_tls with suitable set of test cases between
them.
Signed-off-by: Jouni Malinen <j@w1.fi>
Test case sequence "persistent_group_channel scan_bss_expiration_count"
was failing with UML when using time travel. This seemed to be because
there was no explicit wait to confirm that the AP has been fully
disabled before running the next scan. Work around this by verifying
that hostapd has terminated the BSS and waiting a bit after that before
proceeding.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>